VpCI-369D Oil Based Temporary Coating

VpCI-369D Oil Based Temporary Coating

PRODUCT DESCRIPTION:

VpCI®-369 D is an oil-based temporary coating that provides protection in harsh, outdoor, sheltered applications. Provides multi-metal protection. Excellent lubricity. Can be matched to some custom colors.

Service Hotline:
+86-0532-80989502,+86-135-0535-2885
E-Mail:zzgvci@163.com

NSN 8030-00-244-1295, 244-1297, 244-1298, 01-149-1731

UFI: RQ60-A0G6-600A-8GA8

PACKAGING & STORAGE

VpCI®-369 D is available in 5 gallon (19 L) pails, 55 gallon (208 L) metal drums, liquid totes, and bulk.

To ensure best product performance, store in original packaging, indoors, and out of direct sunlight at 40-100 °F (4-38 °C).

Shelf life: 1 year

CHARACTERISTICS/TECHNICAL DATA

Volume Solids

94%

Gloss (ASTM D532)

NA

VOCs (ASTM D3960)

0

Viscosity

35-40 sec #2 Zahn Cup, 80 CPS @ 20C

Pencil Hardness (ASTM D3363)

NA

Spreading Rate

1508 ft2/gal @ 1.0 mils DFT (36.9 m2/L @ 25um)

Weight per Gallon

7.65 lbs/gal (0.91 kg/L)

Flash Point

234 °F (112 °C)

Recommended DFT

1.0-3.0 mils (25-75 um)

Recommended WFT

1.0-3.0 mils (25-75 um)

Dry to Touch

NA

Dry to Handle

NA

Recoat Time

NA

Force Dry

NA

Full Cure

NA

Salt Spray (ASTM B117)

100 hrs

Humidity (ASTM D1748)

1000 hrs

Adhesion (ASTM D3359)

NA

Flexibility (ASTM D522)

½" mandrel (1.27cm)


APPLICATION

Surface Preparation

Substrate should be free of grease, oil, dirt, fingerprints, drawing compounds, rust inhibitors (except Cortec® ap- proved), or any other surface contamination that could affect adhesion. For production line applications, use VpCI®- 440 or similar phosphatizing pre-treatment. For structural steel applications, Cortec® recommends a minimum of a NACE #3/ SSPC-SP6 commercial blast clean. Consult Cortec® Technical Service and/or test system adhesion prior to full scale application.

Note: Power agitate to a uniform consistency using a “squirrel cage” type mixer, hand-held drill mixer, or other equivalent method. VpCI®-369 D can be applied by spray, roll, brush, or dip.

Typical Equipment Setups

HVLP / Conventional Spray
•Tip 0.02”-0.11” (0.5-2.8 mm) dependent upon pressures and viscosity
•Air Pressure 45-55 psi
•Fluid Pressure 10 psi
•Fluid hose should be ⅜” (0.95 cm) I.D. with a maximum length of 50 feet (15.2 m). Pot should always have dual regulation and be kept at same elevation as spray gun.

Air Assisted Airless / Airless
•Tip 0.015”-0.035” (0.38-0.89 mm) dependent upon pres- sures and viscosity
•Pressure 1800-2500 psi
•Hose should be ⅜” (0.95 cm) I.D. minimum, but a ¼”
•(0.64 cm) I.D. whip end section may be used for ease of application. A maximum length of 100 feet (30.5 m) is suggested.

Cleanup

Clean tools/equipment immediately after use with Butyl Ac- etate when paint is still wet. When dry, use Butyl Cellusolve or MEK. Follow mfg’s safety recommendations when using any solvent.


Previous:VpCI-705 Fuel Additive

Next:nothing

Qingdao Cortec Rust Proof Materials Co., Ltd.,               

Wechat QR code on the left side of the website

Qingdao Cortec Rust Proof Materials Co., Ltd.,

Consultation hotline:0532-80989502

Sales Hotline:135-0535-2885

E-mail:zzgvci@163.com

QQ:592192408

Address:Room 2073, No. 12, chongmingdao
East Road, Qingdao Economic Development Zone

Alibaba store:https://shop1420649126784.1688.com

Copyright:Qingdao Cortec Rust Proof Materials Co., Ltd.