VpCI-396Moisture Cure Urethane Primer
PRODUCT DESCRIPTION:
VpCI®-396 is a fast drying, solvent-based moisture cure urethane one coat system (primer & topcoat) that can be applied DTM (Direct to Metal) and provides protection in harsh, outdoor, unsheltered applications.
The complex mixture of non-toxic, organic inhibitors offers protection that competes with most paints and zinc-rich primers. Provides multi-metal protection. Can be matched to most custom colors.
PACKAGING & STORAGE
VpCI®-396 is available in 5 gallon (19 liter) pails. Partially used containers must be purged with nitrogen.
Product shelf life is 1 year.
CHARACTERISTICS/TECHNICAL DATA
Volume Solids |
56.20% |
Gloss (ASTM D532) |
30-50 |
VOCs (ASTM D3960) |
3.1 lbs/gal (371 g/l) |
Viscosity |
55-65 sec+ Zahn#3 |
Pencil Hardness (ASTM D3363) |
2H |
Spreading Rate |
901 sq.ft/gal @ 1.0 mils DFT (22.1 sq.m/l @ 25 μm) |
Weight per Gallon |
9.39 lbs/gal (1.13 kg/l) |
Flash Point |
77°F (25°C) |
Recommended DFT |
2.0-3.0 mils (50-75 μm) |
Recommended WFT |
3.5-5.3 mils (88-130 μm) |
Dry to Touch |
2-3 hrs |
Dry to Handle |
4-6 hrs |
Recoat Time |
Dry to touch - 72 hrs, sand thereafter |
Force Dry |
15-20 min @ 150°F (65°C) |
Full Cure |
3-7 days |
Salt Spray (ASTM B117) |
750 hrs |
Humidity (ASTM D1748) |
1000 hrs |
Adhesion (ASTM D3359) |
5B |
Flexibility (ASTM D522) |
1/2" mandrel (1.27cm) |
APPLICATION
Surface Preparation
Substrate should be free of grease, oil, dirt, fingerprints, drawing compounds, rust inhibitors, or any other surface contam- ination that could affect adhesion. For production line applications, use VpCI-440 or similar phosphatizing pre-treatment. For structural steel applications, Cortec® recommends a minimum of a NACE #3/ SSPC-SP6 commercial blast clean. Consult Cortec® Technical Service and/or test system adhesion prior to full scale application.
A wash primer such as VpCI-373 green applied at 0.5-1.0 mils (12.5-25 microns) is recommended before applying the VpCI®- 396 to aluminum, galvanized or plated substrates. When solvent based topcoats are applied over VpCI-396, compatibility must be checked. Cortec® recommended topcoats include VpCI®-280, 380, 381, 386, 387, 390, 392, 382, and 384.
Note: Make sure dew point is more than 5°F (2°C) less than air temperature for application. Humidity must be min. 20%, max. 80%. Power agitate to a uniform consistency using a “squirrel cage” type mixer, hand-held drill mixer, or other equivalent method. VpCI®-396 can be applied by spray, roll, brush, or dip
Typical Equipment Setups
HVLP / Conventional Spray
•Tip .009”-.021” *dependent upon pressures and viscosity
•Air Pressure 45-55 psi
•Fluid Pressure 10 psi
•Fluid hose should be 3/8” (0.95 cm) I.D. with a maximum length of 50 feet (15.2 m). Pot should always have dual regula- tion and be kept at same elevation as spray gun.
Air Assisted Airless / Airless
•Tip .015”-.035” *dependent upon pressures and viscosity
•Pressure 1800-2500 psi
•Hose should be 3/8” (0.95 cm) I.D. minimum, but a ¼”
•(0.64 cm) I.D. whip end section may be used for ease of application. A maximum length of 100 feet (30.5 m) is suggested.
Cleanup
Clean tools/equipment immediately after use with Butyl Acetate when paint is still wet. When dry, use Butyl Cellusolve or MEK. Follow mfg’s safety recommendations when using any solvent.